TrueLoad
Real Data. Real Fast. Capacity Confirmed.
Smith – 45 Elm Street
Auto-saved at 1:33:15 PM
+ New Projects Save
Project Info
Service Info
AMI Data
Equipment
Results
Report
Customer Information
Customer Name
Address
45 Elm Street
City/Town
Burlington
State
VT
ZIP Code
05401
Email
s.smith@email.com
Preparer Information ↻ Load My Details
Prepared By
License Number
Service Info
Service Rating
Voltage
Panel Bus Rating
Service Type
Service Voltage Description
120/240V single-phase
AMI Data Upload
Drop CSV, Excel, or XML file here
or click to browse — any format accepted
GMP_AMI_Data_2024.csv
Data Points
Peak Demand
12 mo
Data Period
Equipment
Equipment NameTypeMCAkVAConcurrent
Heat Pump Yes
+ Add Equipment
PASS
Existing service has adequate capacity for the proposed new loads under NEC 220.87.
NEC 220.87 Load Calculation
Existing Demand
125% of Existing Demand
New Concurrent Load
Adjusted Demand
Service Capacity
Available Margin
TrueLoad Measured Demand Report
NEC 220.87 Service Adequacy Evaluation
TrueLoad
Customer & Project Info
Customer: Sarah Smith
Address: 45 Elm St, Burlington VT
Preparer: J. Marin, Lic. Electrician
Date: 04/14/2026
Service Data
Rating: 200A Voltage: 240V Capacity: 38.4 kVA Type: Overhead
AMI Demand Data
35,040 data points · 12 months · Peak: 14.2 kW
NEC 220.87 Calculation
Existing Demand11.8 kVA
125% Existing Demand14.8 kVA
New Concurrent Load6.0 kVA
Adjusted Demand20.8 kVA
Service Capacity38.4 kVA
Available Margin+17.6 kVA
PASS — Service Adequate
Available margin: +17.6 kVA · Ready for AHJ submission
J. Marin
Lic. Electrician · EL-00492
Print Report
Complete PDF report — ready to submit to the AHJ. This evaluation covers service capacity under NEC 220.87 only. Final approval remains with the Authority Having Jurisdiction.